installation instructions for details. NOTE: The coil cabinet has six screw clearance holes which should be aligned with the furnace engagement holes. Secure the coil cabinet to the furnace or air handler using six field-provided #8 X 1" screws. Air Leakage All indoor cabinets MUST be taped after installation to seal against any air leaks. If a coil is part of the total system installation, use the In-staller’s Guide packaged with the furnaces, outdoor sections, and thermostat for physically installing those components.! CAUTION Caution: This coil is pressurized with psig of dry air. Blueridge BC1 and BC4X Evaporator Coil Installation Manual (PDF, KB) Blueridge BC1P, BC4X, BH1P Evaporator Coil Specifications Sheet (PDF, KB) BC Evaporator Coil Specifications Sheets (PDF, MB) Blueridge Unitary Equipment Limited Warranty (PDF, KB) Blueridge Coil Installation Instructions.
Installation Instructions Evaporator Coil A Coil - Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS INSTALLATION OF EVAPORATOR COILS Upflow coil installation The cased coil is designed to fit furnaces of the same width. 1. Set coil in place on upflow furnace discharge air. Procedure 3 — Installation of Evaporator Coil Procedure 4 — Connect Refrigerant Piping Procedure 5 — Connect Refrigerant Liquid Use this instruction manual to install indoor coils on upflow or downflow furnaces. (See Fig. 1.) Do not install coil in horizontal position. Models CNPVU/CNRVU have factory-installed. INSTALLATION INSTRUCTIONS Evaporator Coil ** Manufactured By Allied Air Enterprises LLC A Lennox International, Inc. Company Metropolitan Drive West Columbia, SC K These instructions must be read before any installation. WARNING.
Installing Air Seals After Evaporator Coil Installation IMPORTANT: Evaporator coil assembly should not be removed after refrigerant lines have been connected and brazed. 1. Disconnect power. 2. Remove evaporator coil assembly from the furnace. 3. Install the air seals, hooking the top flange over the internal sides of the drain opening as shown. Installation A Figure 1 - Typical Coil Installation on Furnace INSTALLATION OF EVAPORATOR COILS Upflow coil installation The cased coil is designed to fit furnaces of the same width. 1. Set coil in place on upflow furnace discharge air opening. 2. Ensure coil is level for proper condensate drainage. Do not tip coil toward condensate drain. Coil casing need. INSTALLATION INSTRUCTIONS Evaporator Coils, Multipoise EAM4X18−60 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury or.
0コメント